Generate a Solar Permit Package for a design using ABB PVI-12,0-I-OUTD-US-S2
Sign up Learn MoreWith SolarDesignTool, you can create a design from scratch and generate a full PV permit package in as little as 15 minutes.
This page contains information about the ABB PVI-12 inverter. To compare this to other PV inverters, click here.
DC Electrical Properties
- Maximum Input Current
48A (208V)
50A (480V)
50A (600V) - Start Voltage
230V (208V)
200V (480V)
200V (600V) - Max DC Input Voltage 520V
- Peak Power Tracking Voltage
220V - 470V (208V)
250V - 470V (480V)
250V - 470V (600V) - Number of MPPTs 2
- MPPTs Can Be Paralleled Yes
- Maximum Current per MPPT Channel 29A
- Operating Voltage Range 200V - 520V
- Polarity of Ground Either
- DC Disconnect Yes
- DC Terminal Quantity 6
- Includes Fuses for String Inputs No
- Max Rating for String Fuses 15A
- Rating of Included String Fuses not applicable
- DC Input Wire Gauge Range 6 AWG – 6 AWG
- Integrated DC Arc Fault Protection No
AC Electrical Properties
- Rated Power Output
10000W (208V)
12000W (480V)
12000W (600V) - Compatible Utility Voltages 208V, 480V, 600V
- Peak Efficiency
96.5% (208V)
97.3% (480V)
97.3% (600V) - Weighted Efficiency
96% (208V)
97% (480V)
97% (600V) - Maximum Output Current
30A (208V)
16A (480V)
12.8A (600V) - Max OCPD rating data not available
- AC Disconnect Yes
- AC Input Wire Gauge Range 10 AWG – 6 AWG
- Sleep Consumption data not available
- Maximum DC-AC Ratio data not available
- Standby Consumption 8W
Mechanical Characteristics
- Height 37.7in (958mm)
- Width 25.4in (645mm)
- Depth 8.7in (222mm)
- Weight 114lb (51.7kg)
- NEMA Enclosure Rating NEMA 4
- Cooling Method Natural Convection
Environmental Constraints
- Ambient Temperature Range -13°F - 140°F (-25°C - 60°C)
Warranties and Compliances
- Compliances UL 1741, IEEE 1547
- CSI Listed Yes
This web page is not the manufacturer's official data sheet and is not endorsed by the manufacturer in any way. For an official data sheet, please go to ABB's website.