Generate a Solar Permit Package for a design using ABB PVI-12.5-TL-OUTD
Sign up Learn MoreWith SolarDesignTool, you can create a design from scratch and generate a full PV permit package in as little as 15 minutes.
This page contains information about the ABB PVI-12.5-TL-OUTD inverter. To compare this to other PV inverters, click here.
DC Electrical Properties
- Maximum Input Current 18A
- Start Voltage 360V
- Max DC Input Voltage 900V
- Peak Power Tracking Voltage 270V - 750V
- Number of MPPTs 2
- MPPTs Can Be Paralleled Yes
- Maximum Current per MPPT Channel 17A
- Operating Voltage Range 200V - 850V
- Polarity of Ground Floating
- DC Disconnect No
- DC Terminal Quantity 4
- Includes Fuses for String Inputs Yes
- Max Rating for String Fuses 12A
- Rating of Included String Fuses 12A
- DC Input Wire Gauge Range data not available
- Integrated DC Arc Fault Protection No
AC Electrical Properties
- Rated Power Output 12500W
- Compatible Utility Voltages 480V
- Peak Efficiency 97.8%
- Weighted Efficiency 97.2%
- Maximum Output Current 20A
- Max OCPD rating 25A
- AC Disconnect No
- AC Input Wire Gauge Range 12 AWG – 6 AWG
- Sleep Consumption 1W
- Maximum DC-AC Ratio data not available
- Standby Consumption 10W
Mechanical Characteristics
- Height 28.2in (716mm)
- Width 25.4in (645mm)
- Depth 8.8in (224mm)
- Weight 90.4lb (41kg)
- NEMA Enclosure Rating NEMA 1
- Cooling Method Natural Convection
Environmental Constraints
- Ambient Temperature Range -13°F - 140°F (-25°C - 60°C)
Warranties and Compliances
- Compliances data not available
- CSI Listed No
This web page is not the manufacturer's official data sheet and is not endorsed by the manufacturer in any way. For an official data sheet, please go to ABB's website.