Generate a Solar Permit Package for a design using KACO blueplanet 5002xi

With SolarDesignTool, you can create a design from scratch and generate a full PV permit package in as little as 15 minutes.

This page contains information about the KACO blueplanet 5002xi inverter. To compare this to other PV inverters, click here.

DC Electrical Properties

  • Maximum Input Current 40A
  • Start Voltage 200V
  • Max DC Input Voltage 550V
  • Peak Power Tracking Voltage 200V - 510V
  • Number of MPPTs 1
  • Operating Voltage Range 200V - 550V
  • Polarity of Ground Either
  • DC Disconnect Yes
  • DC Terminal Quantity 3
  • Includes Fuses for String Inputs No
  • Max Rating for String Fuses data not available
  • Rating of Included String Fuses not applicable
  • DC Input Wire Gauge Range 8 AWG – 4 AWG
  • Integrated DC Arc Fault Protection No

AC Electrical Properties

  • Rated Power Output 5000W
  • Compatible Utility Voltages 208V, 240V
  • Peak Efficiency 95% (208V)
    95.5% (240V)
  • Weighted Efficiency 95% (208V)
    95.5% (240V)
  • Maximum Output Current 24A
  • Max OCPD rating data not available
  • AC Disconnect Yes
  • AC Input Wire Gauge Range 8 AWG – 4 AWG
  • Sleep Consumption 0.3W
  • Maximum DC-AC Ratio data not available
  • Standby Consumption data not available

Mechanical Characteristics

  • Height 35.9in (911mm)
  • Width 14in (356mm)
  • Depth 9.5in (241mm)
  • Weight 70lb (31.7kg)
  • NEMA Enclosure Rating NEMA 3R
  • Cooling Method Forced Air

Environmental Constraints

  • Ambient Temperature Range -5.8°F - 104°F (-21°C - 40°C)

Warranties and Compliances

  • Compliances UL 1741, IEEE 1547
  • CSI Listed Yes

This web page is not the manufacturer's official data sheet and is not endorsed by the manufacturer in any way. For an official data sheet, please go to KACO's website.