DC Electrical Properties

  • Maximum Input Current 125A
  • Start Voltage 21V
  • Max DC Input Voltage 34V
  • Peak Power Tracking Voltage 21V - 34V
  • Number of MPPTs 1
  • Operating Voltage Range 21V - 34V
  • Polarity of Ground Either
  • DC Disconnect No
  • DC Terminal Quantity 1
  • Includes Fuses for String Inputs No
  • Max Rating for String Fuses data not available
  • Rating of Included String Fuses not applicable
  • DC Input Wire Gauge Range data not available
  • Integrated DC Arc Fault Protection No

AC Electrical Properties

  • Rated Power Output 2500W
  • Compatible Utility Voltages 120V
  • Peak Efficiency 92%
  • Weighted Efficiency 92%
  • Maximum Output Current 70A
  • Max OCPD rating 250A
  • AC Disconnect No
  • AC Input Wire Gauge Range data not available
  • Sleep Consumption 3W
  • Maximum DC-AC Ratio data not available
  • Standby Consumption 34W

Mechanical Characteristics

  • Height 16.1in (410mm)
  • Width 13in (330mm)
  • Depth 8.3in (210mm)
  • Weight 63.9lb (29kg)
  • NEMA Enclosure Rating NEMA 1
  • Cooling Method Natural Convection

Environmental Constraints

  • Ambient Temperature Range -40°F - 140°F (-40°C - 60°C)

Warranties and Compliances

  • Compliances UL 1741
  • CSI Listed No

This web page is not the manufacturer's official data sheet and is not endorsed by the manufacturer in any way. For an official data sheet, please go to OutBack's website.