Generate a Solar Permit Package for a design using Schneider GT2.8
Sign up Learn MoreWith SolarDesignTool, you can create a design from scratch and generate a full PV permit package in as little as 15 minutes.
This page contains information about the Schneider GT2.8 inverter. To compare this to other PV inverters, click here.
DC Electrical Properties
- Maximum Input Current
14.9A (208V)
15.4A (240V) - Start Voltage 170V
- Max DC Input Voltage 600V
- Peak Power Tracking Voltage 195V - 550V
- Number of MPPTs 1
- Polarity of Ground Negative
- DC Disconnect Yes
- DC Terminal Quantity 3
- Includes Fuses for String Inputs No
- Max Rating for String Fuses data not available
- Rating of Included String Fuses not applicable
- DC Input Wire Gauge Range 14 AWG – 6 AWG
- Integrated DC Arc Fault Protection No
AC Electrical Properties
- Rated Power Output
2700W (208V)
2800W (240V) - Compatible Utility Voltages 208V, 240V
- Peak Efficiency
94.6% (208V)
95% (240V) - Weighted Efficiency
93.5% (208V)
94% (240V) - Maximum Output Current
13A (208V)
11.7A (240V) - Max OCPD rating data not available
- AC Disconnect Yes
- AC Input Wire Gauge Range 14 AWG – 6 AWG
- Sleep Consumption 1W
- Maximum DC-AC Ratio data not available
- Standby Consumption 0W
Mechanical Characteristics
- Height 28.5in (724mm)
- Width 15.9in (403mm)
- Depth 5.7in (144mm)
- Weight 48.9lb (22.2kg)
- NEMA Enclosure Rating NEMA 3R
- Cooling Method Natural Convection
Environmental Constraints
- Ambient Temperature Range -13°F - 149°F (-25°C - 65°C)
Warranties and Compliances
- Compliances UL 1741, IEEE 1547
- CSI Listed Yes
This web page is not the manufacturer's official data sheet and is not endorsed by the manufacturer in any way. For an official data sheet, please go to Schneider's website.