DC Electrical Properties
- Maximum Input Current 32A
- Start Voltage 200V
- Max DC Input Voltage 600V
- Peak Power Tracking Voltage 140V - 530V
- Number of MPPTs 2
- MPPTs Can Be Paralleled Yes
- Maximum Current per MPPT Channel 20A
- Operating Voltage Range 120V - 600V
- Polarity of Ground Floating
- DC Disconnect Yes
- DC Terminal Quantity 4
- Includes Fuses for String Inputs No
- Max Rating for String Fuses 20A
- Rating of Included String Fuses not applicable
- DC Input Wire Gauge Range 10 AWG – 4 AWG
- Integrated DC Arc Fault Protection No
AC Electrical Properties
- Rated Power Output
4200W (208V)
4600W (240V)
4600W (277V) - Compatible Utility Voltages 208V, 240V, 277V
- Peak Efficiency 97%
- Weighted Efficiency 96%
- Maximum Output Current 20A
- Max OCPD rating
25A (208V)
25A (240V)
datasheet.notAvailable (277V) - AC Disconnect No
- AC Input Wire Gauge Range 10 AWG – 4 AWG
- Sleep Consumption 0.6W
- Maximum DC-AC Ratio 1.43
- Standby Consumption 8W
Mechanical Characteristics
- Height 33.8in (859mm)
- Width 12.8in (325mm)
- Depth 8.7in (222mm)
- Weight 47lb (21.3kg)
- NEMA Enclosure Rating NEMA 4
- Cooling Method Forced Air
Environmental Constraints
- Ambient Temperature Range -13°F - 140°F (-25°C - 60°C)
Warranties and Compliances
- Compliances UL 1741
- CSI Listed Yes