Warning This model has been discontinued by the manufacturer.
Generate a Solar Permit Package for a design using Yaskawa-Solectria PVI 60KW
Sign up Learn MoreWith SolarDesignTool, you can create a design from scratch and generate a full PV permit package in as little as 15 minutes.
This page contains information about the Yaskawa-Solectria PVI 60KW inverter. To compare this to other PV inverters, click here.
DC Electrical Properties
- Maximum Input Current 211A
- Start Voltage 380V
- Max DC Input Voltage 600V
- Peak Power Tracking Voltage 285V - 500V
- Number of MPPTs 1
- Operating Voltage Range 285V - 600V
- Polarity of Ground Either
- DC Disconnect Yes
- DC Terminal Quantity 8
- Includes Fuses for String Inputs No
- Max Rating for String Fuses data not available
- Rating of Included String Fuses not applicable
- DC Input Wire Gauge Range 14 AWG – 750 MCM
- Integrated DC Arc Fault Protection No
AC Electrical Properties
- Rated Power Output 60000W
- Compatible Utility Voltages 208V, 240V, 480V, 600V
- Peak Efficiency
96.7% (208V)
97.8% (240V)
96.5% (480V)
96.5% (600V) - Weighted Efficiency
96% (208V)
97% (240V)
96% (480V)
96% (600V) - Maximum Output Current
167A (208V)
144A (240V)
72A (480V)
58A (600V) - Max OCPD rating data not available
- AC Disconnect Yes
- AC Input Wire Gauge Range 4 AWG – 250 MCM
- Sleep Consumption 0W
- Maximum DC-AC Ratio data not available
- Standby Consumption 3W
Mechanical Characteristics
- Height 78.2in (1,986mm)
- Width 53in (1,346mm)
- Depth 33in (838mm)
- Weight 1,452.8lb (659kg)
- NEMA Enclosure Rating NEMA 3R
- Cooling Method Forced Air
Environmental Constraints
- Ambient Temperature Range -40°F - 131°F (-40°C - 55°C)
Warranties and Compliances
- Compliances UL 1741, IEEE 1547
- CSI Listed Yes
This web page is not the manufacturer's official data sheet and is not endorsed by the manufacturer in any way. For an official data sheet, please go to Yaskawa-Solectria's website.